Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Magn Reson Imaging ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558490

RESUMO

BACKGROUND: Automated 4D flow MRI valvular flow quantification without time-consuming manual segmentation might improve workflow. PURPOSE: Compare automated valve segmentation (AS) to manual (MS), and manually corrected automated segmentation (AMS), in corrected atrioventricular septum defect (c-AVSD) patients and healthy volunteers, for assessing net forward volume (NFV) and regurgitation fraction (RF). STUDY TYPE: Retrospective. POPULATION: 27 c-AVSD patients (median, 23 years; interquartile range, 16-31 years) and 24 healthy volunteers (25 years; 12.5-36.5 years). FIELD STRENGTH/SEQUENCE: Whole-heart 4D flow MRI and cine steady-state free precession at 3T. ASSESSMENT: After automatic valve tracking, valve annuli were segmented on time-resolved reformatted trans-valvular velocity images by AS, MS, and AMS. NFV was calculated for all valves, and RF for right and left atrioventricular valves (RAVV and LAVV). NFV variation (standard deviation divided by mean NFV) and NFV differences (NFV difference of a valve vs. mean NFV of other valves) expressed internal NFV consistency. STATISTICAL TESTS: Comparisons between methods were assessed by Wilcoxon signed-rank tests, and intra/interobserver variability by intraclass correlation coefficients (ICCs). P < 0.05 was considered statistically significant, with multiple testing correction. RESULTS: AMS mean analysis time was significantly shorter compared with MS (5.3 ± 1.6 minutes vs. 9.1 ± 2.5 minutes). MS NFV variation (6.0%) was significantly smaller compared with AMS (6.3%), and AS (8.2%). Median NFV difference of RAVV, LAVV, PV, and AoV between segmentation methods ranged from -0.7-1.0 mL, -0.5-2.8 mL, -1.1-3.6 mL, and - 3.1--2.1 mL, respectively. Median RAVV and LAVV RF, between 7.1%-7.5% and 3.8%-4.3%, respectively, were not significantly different between methods. Intraobserver/interobserver agreement for AMS and MS was strong-to-excellent for NFV and RF (ICC ≥0.88). DATA CONCLUSION: MS demonstrates strongest internal consistency, followed closely by AMS, and AS. Automated segmentation, with or without manual correction, can be considered for 4D flow MRI valvular flow quantification. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

2.
J Pers Med ; 14(2)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38392621

RESUMO

BACKGROUND: We aimed to evaluate whether baseline GLS (global longitudinal strain), NT-proBNP, and changes in these after cardiac resynchronization therapy (CRT) can predict long-term clinical outcomes and the echocardiographic-based response to CRT (defined by 15% relative reduction in left ventricular end-systolic volume). METHODS: We enrolled 143 patients with stable ischemic heart failure (HF) undergoing CRT-D implantation. NT-proBNP and echocardiography were obtained before and 6 months after. The patients were followed up (median: 58 months) for HF-related deaths and/or HF hospitalizations (primary endpoint) or HF-related deaths (secondary endpoint). RESULTS: A total of 84 patients achieved the primary and 53 the secondary endpoint, while 104 patients were considered CRT responders and 39 non-responders. At baseline, event-free patients had higher absolute GLS values (p < 0.001) and lower NT-proBNP serum levels (p < 0001) than those achieving the primary endpoint. A similar pattern was observed in favor of CRT responders vs. non-responders. On Cox regression analysis, baseline absolute GLS value (HR = 0.77; 95% CI, 0.51-1.91; p = 0.002) was beneficially associated with lower primary endpoint incidence, while baseline NT-proBNP levels (HR = 1.55; 95% CI, 1.43-2.01; p = 0.002) and diabetes presence (HR = 1.27; 95% CI, 1.12-1.98; p = 0.003) were related to higher primary endpoint incidence. CONCLUSIONS: In HF patients undergoing CRT-D, baseline GLS and NT-proBNP concentrations may serve as prognostic factors, while they may predict the echocardiographic-based response to CRT.

3.
Int J Cardiovasc Imaging ; 40(1): 15-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37815685

RESUMO

Bedside quantification of stroke volume (SV) and left ventricular ejection fraction (LVEF) is valuable in hemodynamically compromised patients. Miniaturized handheld ultrasound (HAND) devices are now available for clinical use. However, the performance level of HAND devices for quantified cardiac assessment is yet unknown. The aim of this study was to compare the validity of HAND measurements with standard echocardiography (SE) and three-dimensional echocardiography (3DE). Thirty-six patients were scanned with HAND, SE and 3DE. LVEF and SV quantification was done with automated software for the HAND, SE and 3DE dataset. The image quality of HAND and SE was evaluated by scoring segmental endocardial border delineation (2 = good, 1 = poor, 0 = invisible). LVEF and SV of HAND was evaluated against SE and 3DE using correlation and Bland-Altman analysis. The correlation, bias, and limits of agreement (LOA) between HAND and SE were 0.68 [0.46:0.83], 1.60% [- 2.18:5.38], and 8.84% [- 9.79:12.99] for LVEF, and 0.91 [0.84:0.96], 1.32 ml [- 0.36:4.01], 15.54 ml [- 18.70:21.35] for SV, respectively. Correlation, bias, and LOA between HAND and 3DE were 0.55 [0.6:0.74], - 0.56% [- 2.27:1.1], and 9.88% [- 13.29:12.17] for LVEF, and 0.79 [0.62:0.89], 6.78 ml [2.34:11.21], 12.14 ml [- 26.32:39.87] for SV, respectively. The image quality scores were 9.42 ± 2.0 for the apical four chamber views of the HAND dataset and 10.49 ± 1.7 for the SE dataset and (P < 0.001). Clinically acceptable accuracy, precision, and image quality was demonstrated for HAND measurements compared to SE. In comparison to 3DE, HAND showed a clinically acceptable accuracy and precision for LVEF quantification.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Valor Preditivo dos Testes , Ecocardiografia , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes
4.
JAMA Netw Open ; 6(7): e2323112, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37436747

RESUMO

Importance: It is suggested that patients with Cutibacterium acnes endocarditis often present without fever or abnormal inflammatory markers. However, no study has yet confirmed this statement. Objective: To assess the clinical characteristics and outcomes of patients with C acnes endocarditis. Design, Setting, and Participants: A case series of 105 patients presenting to 7 hospitals in the Netherlands and France (4 university hospitals and 3 teaching hospitals) with definite endocarditis according to the modified Duke criteria between January 1, 2010, and December 31, 2020, was performed. Clinical characteristics and outcomes were retrieved from medical records. Cases were identified by blood or valve and prosthesis cultures positive for C acnes, retrieved from the medical microbiology databases. Infected pacemaker or internal cardioverter defibrillator lead cases were excluded. Statistical analysis was performed in November 2022. Main Outcomes and Measures: Main outcomes included symptoms at presentation, presence of prosthetic valve endocarditis, laboratory test results at presentation, time to positive results of blood cultures, 30-day and 1-year mortality rates, type of treatment (conservative or surgical), and endocarditis relapse rates. Results: A total of 105 patients (mean [SD] age, 61.1 [13.9] years; 96 men [91.4%]; 93 patients [88.6%] with prosthetic valve endocarditis) were identified and included. Seventy patients (66.7%) did not experience fever prior to hospital admission, nor was it present at hospitalization. The median C-reactive protein level was 3.6 mg/dL (IQR, 1.2-7.5 mg/dL), and the median leukocyte count was 10.0 × 103/µL (IQR, 8.2-12.2 × 103/µL). The median time to positive blood culture results was 7 days (IQR, 6-9 days). Surgery or reoperation was indicated for 88 patients and performed for 80 patients. Not performing the indicated surgical procedure was associated with high mortality rates. Seventeen patients were treated conservatively, in accordance with the European Society of Cardiology guideline; these patients showed relatively high rates of endocarditis recurrence (5 of 17 [29.4%]). Conclusions and Relevance: This case series suggests that C acnes endocarditis was seen predominantly among male patients with prosthetic heart valves. Diagnosing C acnes endocarditis is difficult due to its atypical presentation, with frequent absence of fever and inflammatory markers. The prolonged time to positivity of blood culture results further delays the diagnostic process. Not performing a surgical procedure when indicated seems to be associated with higher mortality rates. For prosthetic valve endocarditis with small vegetations, there should be a low threshold for surgery because this group seems prone to endocarditis recurrence.


Assuntos
Doenças Transmissíveis , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/complicações , Eletrocardiografia
6.
Ann Lab Med ; 43(3): 253-262, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36544337

RESUMO

Background: Heart failure (HF) biomarkers have prognostic value. The aim of this study was to combine HF biomarkers into an objective classification system for risk stratification of patients with HF. Methods: HF biomarkers were analyzed in a population of HF outpatients and expressed relative to their cut-off values (N-terminal pro-B-type natriuretic peptide [NT-proBNP] >1,000 pg/mL, soluble suppression of tumorigenesis-2 [ST2] >35 ng/mL, growth differentiation factor-15 [GDF-15] >2,000 pg/mL, and fibroblast growth factor-23 [FGF-23] >95.4 pg/mL). Biomarkers that remained significant in multivariable analysis were combined to devise the Heartmarker score. The performance of the Heartmarker score was compared to the widely used New York Heart Association (NYHA) classification based on symptoms during ordinary activity. Results: HF biomarkers of 245 patients were analyzed, 45 (18%) of whom experienced the composite endpoint of HF hospitalization, appropriate implantable cardioverter-defibrillator shock, or death. HF biomarkers were elevated more often in patients that reached the composite endpoint than in patients that did not reach the endpoint. NT-proBNP, ST2, and GDF-15 were independent predictors of the composite endpoint and were thus combined as the Heartmarker score. The event-free survival and distance covered in 6 minutes of walking decreased with an increasing Heartmarker score. Compared with the NYHA classification, the Heartmarker score was better at discriminating between different risk classes and had a comparable relationship to functional capacity. Conclusions: The Heartmarker score is a reproducible and intuitive model for risk stratification of outpatients with HF, using routine biomarker measurements.


Assuntos
Insuficiência Cardíaca , Humanos , Biomarcadores , Fator 15 de Diferenciação de Crescimento/sangue , Fator 15 de Diferenciação de Crescimento/química , Insuficiência Cardíaca/diagnóstico , Proteína 1 Semelhante a Receptor de Interleucina-1 , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química , Fragmentos de Peptídeos , Prognóstico , Fator de Crescimento de Fibroblastos 23/sangue , Fator de Crescimento de Fibroblastos 23/química
7.
J Ultrason ; 22(90): e168-e173, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36482930

RESUMO

Aim: Response to cardiac resynchronization therapy varies significantly among patients, with one third of them failing to demonstrate left ventricular reverse remodeling after cardiac resynchronization therapy. Left atrial size and function is increasingly recognized as a marker of disease severity in the heart failure population. The aim of this study was to evaluate whether echocardiographic left atrial indices predict left ventricular reverse remodeling after cardiac resynchronization therapy. Materials and methods: Ninety-nine cardiac resynchronization therapy candidates were prospectively included in the study and underwent echocardiography before and 3-months after cardiac resynchronization therapy implantation. Cardiac resynchronization therapy response was defined as a 15% relative reduction in left ventricular end-systolic volume. Indexed left atrial volume, left atrial reservoir strain, left ventricular end-diastolic volume, and left ventricular ejection fraction along with other known predictors of cardiac resynchronization therapy response (gender, etiology of heart failure, presence of typical left bundle branch block pattern, QRS duration >150 ms) were included in a multivariate logistic regression model to identify predictors for cardiac resynchronization therapy response. Results: Cardiac resynchronization therapy response occurred in n = 63 (64%) patients. The presence of a typical left bundle branch block (OR 4.2, 95 CI: 1.4-12.1, p = 0.009), QRS duration >150 ms (OR 4.2, 95 CI: 1.4-11.0, p = 0.029), and left atrial volume index (OR: 0.6, 95 CI: 0.4-0.9, p = 0.012) remained the only significant predictors for cardiac resynchronization therapy response after three months. None of the baseline left ventricular parameters showed an independent predictive value. Conclusion: Left atrial size at baseline is an independent predictor and is inversely proportional to left ventricular volumetric reverse remodeling in cardiac resynchronization therapy candidates.

8.
PLoS One ; 17(7): e0271588, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35839240

RESUMO

AIMS: Progressive changes to left atrial (LA) structure and function following mitral regurgitation (MR) remain incompletely understood. This study aimed to demonstrate potential underlying mechanisms using experimental canine models and computer simulations. METHODS: A canine model of MR was created by cauterization of mitral chordae followed by radiofrequency ablation-induced left bundle-branch block (LBBB) after 4 weeks (MR-LBBB group). Animals with LBBB alone served as control. Echocardiography was performed at baseline, acutely after MR induction, and at 4 and 20 weeks, and correlated with histology and computer simulations. RESULTS: Acute MR augmented LA reservoir and contractile strain (40±4 to 53±6% and -11±5 to -22±9% respectively, p<0.05). LA fractional area change increased significantly (47±4 to 56±4%, p<0.05) while LA end-systolic area remained unchanged (7.2±1.1 versus 7.9±1.1 cm2 respectively, p = 0.08). LA strain 'pseudonormalized' after 4 weeks and decompensated at 20 weeks with both strains decreasing to 25±6% and -3±2% respectively (p<0.05) together with a progressive increase in LA end-systolic area (7.2±1.1 to 14.0±6.3 cm2, p<0.05). In the LBBB-group, LA remodeling was less pronounced. Histology showed a trend towards increased interstitial fibrosis in the LA of the MR-LBBB group. Computer simulations indicated that the progressive changes in LA structure and function are a combination of progressive eccentric remodeling and fibrosis. CONCLUSION: MR augmented LA strain acutely to supranormal values without significant LA dilation. However, over time, LA strain gradually decreases (pseudornormal and decompensated) with LA dilation. Histology and computer simulations indicated a correlation to a varying degree of LA eccentric remodeling and fibrosis.


Assuntos
Remodelamento Atrial , Insuficiência da Valva Mitral , Animais , Bloqueio de Ramo , Cães , Ecocardiografia , Fibrose , Átrios do Coração , Insuficiência da Valva Mitral/diagnóstico por imagem
9.
Pacing Clin Electrophysiol ; 45(6): 726-732, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35510824

RESUMO

BACKGROUND: Right ventricular pacing (RVP) induces abnormal electrical activation and asynchronous ventricular contraction and leads to pacing induced cardiomyopathy (PICM) in 10%-20% of patients. Cardiac resynchronization therapy (CRT) utilizing biventricular pacing (BVP) is the recommended treatment. Left bundle branch pacing (LBBP) is a novel physiological pacing technique which may serve as an alternative to CRT. This study assessed feasibility and outcomes of LBBP delivered CRT in patients with PICM. METHODS: Total 20 consecutive patients with PICM who received an upgrade of their pacemaker to LBBP were prospectively studied. Acute success rate, complications, functional and echocardiographic response, and hospitalization for heart failure within 6 months from implantation were evaluated. RESULTS: LBBP was successfully delivered in all patients. Median duration of RVP before upgrade to LBBP was 3.8 years and the RVP was 99%. LBBP resulted in significant QRS narrowing (from 193 ± 18 ms to 130 ± 17 ms [p < .001]), improvement in LVEF (from 32% ± 6 % to 47% ± 8% [p < .001]) and NYHA class (from 2.8 ± 0.4 to 1.4 ± 0.5 [p < .001]) at 6 months. No LBBP-related complications occurred. No patients were hospitalized for heart failure or died. CONCLUSION: LBBP is feasible and safe in delivering CRT in PICM. Preliminary analyses demonstrated significant electrical resynchronization and favorable improvement in LV function and NYHA functional class at short term follow-up. Data needs to be validated in large randomized controlled trials.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Estudos de Viabilidade , Humanos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
10.
BMC Cardiovasc Disord ; 22(1): 104, 2022 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-35287575

RESUMO

BACKGROUND: The left atrium (LA) is a key player in the pathophysiology of systolic and diastolic heart failure (HF). Speckle tracking derived LA reservoir strain (LASr) can be used as a prognostic surrogate for elevated left ventricular filling pressure similar to NT-proBNP. The aim of the study is to investigate the correlation between LASr and NT-proBNP and its prognostic value with regards to the composite endpoint of HF hospitalization and all-cause mortality within 1 year. METHODS: Outpatients, sent to the echocardiography core lab because of HF, were enrolled into this study. Patients underwent a transthoracic echocardiographic examination, commercially available software was used to measure LASr. Blood samples were collected directly after the echocardiographic examination to determine NT-proBNP. RESULTS: We included 174 HF patients, 43% with reduced, 36% with mildly reduced, and 21% with preserved ejection fraction. The study population showed a strong inverse correlation between LASr and log-transformed NT-proBNP (r = - 0.75, p < 0.01). Compared to NT-proBNP, LASr predicts the endpoint with a comparable specificity (83% vs. 84%), however with a lower sensitivity (70% vs. 61%). CONCLUSION: LASr is inversely correlated with NT-proBNP and a good echocardiographic predictor for the composite endpoint of hospitalization and all-cause mortality in patients with HF. TRIAL REGISTRATION: https://www.trialregister.nl/trial/7268.


Assuntos
Insuficiência Cardíaca , Biomarcadores , Estudos de Coortes , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/epidemiologia , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Prognóstico , Volume Sistólico/fisiologia , Função Ventricular Esquerda
11.
Ned Tijdschr Geneeskd ; 1662022 02 02.
Artigo em Holandês | MEDLINE | ID: mdl-35129893

RESUMO

We report on three patients with infective endocarditis, which differ greatly in clinical manifestations. Infective endocarditis (IE) is defined by, a mostly bacterial, infection of a native or prosthetic heart valve, the endocardial surface or a cardiac device. It is a rare condition, but it's incidence is increasing because of an increased incidence of elderly patients with chronic disease and cardiac devices. IE is heterogeneous in aetiology, clinical manifestations, and course. It can involve almost any organ system. The presentation often remains subtle and varies with nonspecific symptoms ranging from a mild infection to septic shock and multiorgan failure. IE remains a highly mortal disease, since the diagnosis is missed often. A thorough anamnesis and physical examination can be helpful. Blood cultures prior to antibiotics and echocardiography are key diagnostic steps if there's a clinical suspicion of IE.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Idoso , Antibacterianos/uso terapêutico , Ecocardiografia , Endocardite/diagnóstico , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos
12.
J Echocardiogr ; 20(2): 115-123, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34822132

RESUMO

BACKGROUND: Left ventricular (LV) reverse remodeling has been identified as a strong predictor of long-term survival in patients receiving CRT. Interestingly, CRT induces reverse remodeling in the left atrium (LA) as well. It is currently unknown to what extent LA reverse remodeling is correlated to long-term survival after CRT. This study aims to assess the long-term prognostic value of left atrium (LA) reverse remodeling in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Baseline and 3-months follow-up echocardiograms after CRT implantation were prospectively assessed to determine changes in left ventricular end-systolic volume (LVESV), left ventricular ejection fraction (LVEF), left atrial volume (LAV), and left atrial reservoir strain (LASr). Multivariate Cox regression analysis was performed to identify predictors for long-term survival. RESULTS: In our study population of 99 patients with a mean follow-up of 6.3 ± 2.1 years, 43 patients (43%) reached the end-point of all-cause mortality. More extensive LA reverse remodeling, as measured by a relative increase in LASr, was observed in survivors compared to non-survivors (43 [29-64] % vs. 8 [2-28] %, P < 0.001, respectively). After multivariate analysis, delta LASr remained the only significant predictor of mortality [HR per 5%: 0.90 (0.86-0.95); AUC 0.78 (0.68-0.88)]. CONCLUSION: An increase in LASr is associated with favorable long-term outcome after CRT. The observed clinical importance of LA reverse remodeling after CRT asks for further validation in larger prospective cohorts.


Assuntos
Remodelamento Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
13.
J Am Soc Echocardiogr ; 35(1): 105-115.e8, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34389469

RESUMO

BACKGROUND: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER). METHODS: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR. FMR proportionality was graded on preprocedural transthoracic echocardiography using the ratio of the effective regurgitant orifice area to LV end-diastolic volume. Baseline characteristics, follow-up transthoracic echocardiography, and 2-year clinical outcomes were compared between groups. RESULTS: Median LV ejection fraction, effective regurgitant orifice area and LV end-diastolic volume index were 30% (interquartile range [IQR], 25%-35%), 27 mm2, and 107 mL/m2 (IQR, 90-135 mL/m2), respectively. Median effective regurgitant orifice area/LV end-diastolic volume ratio was 0.13 (IQR, 0.10-0.18). Proportionate FMR (pFMR) and disproportionate FMR (dFMR) was present in 123 and 118 patients, respectively. Compared with patients with pFMR, those with dFMR had higher baseline LV ejection fractions (median, 32% [IQR, 27%-39%] vs 26% [IQR, 22%-33%]; P < .01). Early FMR reduction with TEER was more pronounced in patients with dFMR (odds ratio, 0.45; 95% CI, 0.28-0.74; P < .01) than those with pFMR, but not at 12 months (odds ratio, 0.93; 95% CI, 0.53-1.63; P = .80). Overall, in 35% of patients with initial FMR reduction after TEER, FMR deteriorated again at 1-year follow-up. Rates of 2-year all-cause mortality and heart failure hospitalization were 30% (n = 66) and 37% (n = 76), with no differences between dFMR and pFMR. CONCLUSIONS: TEER resulted in more pronounced early FMR reduction in patients with dFMR compared with those with pFMR. Yet after initial improvement, FMR deteriorated in a substantial number of patients, calling into question durable mitral regurgitation reductions with TEER in selected patients. The proportionality framework may not identify durable TEER responders.


Assuntos
Insuficiência da Valva Mitral , Ecocardiografia , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
14.
Ann Card Anaesth ; 24(4): 500-502, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34747766

RESUMO

A 69-year-old patient underwent an urgent aortic valve replacement because of Streptococcus agalactiae endocarditis of his native aortic valve. Since a rapid progression of the former abscess cavity into an aortic root pseudoaneurysm with increasing paravalvular regurgitation during postoperative follow-up, reoperation was performed. In the preoperative transesophageal echocardiography (TEE) images the pseudoaneurysm completely surrounds the left coronary artery (LCA) without any signs of myocardial ischemia.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Reoperação
15.
Medicina (Kaunas) ; 57(5)2021 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-34064932

RESUMO

Background and objectives: Persistent left bundle branch block (P-LBBB) has been associated with poor clinical outcomes of transcatheter aortic valve implantation (TAVI) procedures. We hypothesized that the distance from the aortic valve to the proximal conduction system, expressed as the effective distance between the aortic valve and conduction system (EDACS), can predict the occurrence of P-LBBB in patients undergoing a TAVI procedure. Materials and methods: In a retrospective study, data from 269 patients were analyzed. EDACS was determined using two longitudinal CT sections. Results: Sixty-four of the patients developed P-LBBB. EDACS ranged between -3 and +18 mm. EDACS was significantly smaller in P-LBBB than in non-P-LBBB patients (4.6 (2.2-7.1) vs. 8.0 (5.8-10.2) mm, median values (interquartile range); p < 0.05). Receiver operating characteristic analysis showed an area under the curve of 0.78 for predicting P-LBBB based on EDACS. In patients with EDACS of ≤3 mm and >10 mm, the chance of developing P-LBBB was ≥50% and <10%, respectively. Conclusions: A small EDACS increases the risk for the development of P-LBBB during TAVI by a factor of >25. As EDACS can be measured pre-procedurally, it may be a valuable additional factor to weigh the risks of transcatheter and surgical aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo , Eletrocardiografia , Humanos , Incidência , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Int J Cardiol ; 333: 21-28, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33675889

RESUMO

BACKGROUND: It is already known that high coronary microvascular resistance (Rµ) is linked to altered left ventricular stiffness and might be an early indicator of heart failure with preserved ejection fraction (HFpEF). Left atrial dysfunction, on the other hand, varies according to the grade of left ventricular diastolic dysfunction. This is the first study to use the latest development for invasive assessment of Rµ and to combine it with echocardiographic assessment of left atrial strain during reservoir phase (LASr) by speckle tracking in relation to left ventricular (LV) diastolic function. METHODS AND RESULTS: An invasive angiogram was performed in 97 patients because of suspected ANOCA. All patients underwent comprehensive echocardiography, yet image quality was poor in 15 patients leaving 82 patients to include in the final analysis. In order to compare Rµ with LASr values, patients were divided into 4 groups based upon normal values of Rµ as defined by Fournier et al. The mean LASr was plotted against the four resistance groups. The LASr was 48.6% in the lowest resistance group, and 40.1%, 36.3% and 30.1% in the low intermediate, high intermediate and high resistance group respectively. These differences were significant compared to the lowest resistance group (p < 0.05). Although higher Rµ groups showed more diastolic dysfunction, LASr was already decreased irrespective of the severity of diastolic dysfunction. CONCLUSION: This study shows a relationship between increased Rµ and reduced LASr, that seems to precede conventional measures of left ventricular diastolic dysfunction. This suggests that microvascular dysfunction might be an early indicator for the development of impaired LA function.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Função do Átrio Esquerdo , Átrios do Coração , Humanos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
17.
Artigo em Inglês | MEDLINE | ID: mdl-33001799

RESUMO

Near-field (NF) clutter in echocardiography is depicted as a diffuse haze hindering the visualization of the myocardium and the blood-pool, thereby degrading its diagnostic value. Several clutter filters have been developed, which are limited in patients with contraction motion and rhythm anomalies, and in 3-D ultrasound (US). This study introduces a new NF clutter reduction method, which preserves US speckles required for strain imaging. The filter developed detects the NF clutter region in the spatial frequency domain. The filter employs an oriented, multiscale approach, and assumes the NF clutter to be predominantly present in the highest and lowest bandpass images. These bandpass images were filtered, whilst sparing features in the myocardium and NF clutter-free regions. The performance of the filter was assessed in a volunteer study, in ten 3-D apical and parasternal view acquisitions, and in a retrospective clinical study composed of 20 cardiac patients with different indications for echocardiography. The filter reduced NF clutter in all data sets, whilst preserving all or most of the myocardium. Additionally, it demonstrated a consistent enhancement of image quality, with an increase in contrast of 4.3 dB on average, and generated a clearer myocardial boundary distinction. Furthermore, the speckles were preserved according to the quality index based on local variance, the structural similarity index method, and normalized cross correlation values, being 0.82, 0.92, and 0.95 on average, respectively. Global longitudinal strain measurements on NF clutter reduced images were improved or equivalent compared to the original acquisitions, with an average increase in strain signal-to-noise ratio of 34%.


Assuntos
Ecocardiografia , Humanos , Movimento (Física) , Estudos Retrospectivos , Razão Sinal-Ruído , Ultrassonografia
18.
Comput Methods Programs Biomed ; 198: 105810, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33218707

RESUMO

BACKGROUND AND OBJECTIVE: Left ventricle (LV) dysfunction always occurs at early heart-failure stages, producing variations in the LV flow patterns. Cardiac diagnostics may therefore benefit from flow-pattern analysis. Several visualization tools have been proposed that require ultrafast ultrasound acquisitions. However, ultrafast ultrasound is not standard in clinical scanners. Meanwhile techniques that can handle low frame rates are still lacking. As a result, the clinical translation of these techniques remains limited, especially for 3D acquisitions where the volume rates are intrinsically low. METHODS: To overcome these limitations, we propose a novel technique for the estimation of LV blood velocity and relative-pressure fields from dynamic contrast-enhanced ultrasound (DCE-US) at low frame rates. Different from other methods, our method is based on the time-delays between time-intensity curves measured at neighbor pixels in the DCE-US loops. Using Navier-Stokes equation, we regularize the obtained velocity fields and derive relative-pressure estimates. Blood flow patterns were characterized with regard to their vorticity, relative-pressure changes (dp/dt) in the LV outflow tract, and viscous energy loss, as these reflect the ejection efficiency. RESULTS: We evaluated the proposed method on 18 patients (9 responders and 9 non-responders) who underwent cardiac resynchronization therapy (CRT). After CRT, the responder group evidenced a significant (p<0.05) increase in vorticity and peak dp/dt, and a non-significant decrease in viscous energy loss. No significant difference was found in the non-responder group. Relative feature variation before and after CRT evidenced a significant difference (p<0.05) between responders and non-responders for vorticity and peak dp/dt. Finally, the method feasibility is also shown with 3D DCE-US. CONCLUSIONS: Using the proposed method, adequate visualization and quantification of blood flow patterns are successfully enabled based on low-rate DCE-US of the LV, facilitating the clinical adoption of the method using standard ultrasound scanners. The clinical value of the method in the context of CRT is also shown.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...